APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2934 Issued:1978-06-28
Revised:2011-10-26
Style 2934 Multiple-conductor cable using non-integral jacket.

Rating80 deg C, 150 Vac, Cable flame.
Insulated ConductorLabeled or complying with manufacturer's AWM procedure.
AssemblyConsists of two or more conductors, twisted pairs groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size. Fillers required if necessary to form a relatively smooth round core for extrusion of outer jacket.
ShieldOptional.
CoveringOptional. A 6 mil or heavier Extruded PVC covering may be over the conductor assembly.
JacketExtruded PVC;
Dia. of cable under jacket (inches)Minimum average thickness (mils)Minimum thickness at any point (mils)
0 - 0.7003024
0.701 - 1.0004536
1.001 - 1.5006048
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring or external interconnection of electronic equipment.

UL and the UL Logo are trademarks of UL LLC © 2024