Rating | 80 deg C, 150 Vac, Cable flame. |
|
Insulated Conductor | Labeled or complying with manufacturer's AWM procedure. |
|
Assembly | Consists of two or more conductors, twisted pairs groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size. Fillers required if necessary to form a relatively smooth round core for extrusion of outer jacket. |
|
Shield | Optional. |
|
Covering | Optional. A 6 mil or heavier Extruded PVC covering may be over the conductor assembly. |
|
Jacket | Extruded PVC; |
| Dia. of cable under jacket (inches) | Minimum average thickness (mils) | Minimum thickness at any point (mils) |
| 0 - 0.700 | 30 | 24 |
| 0.701 - 1.000 | 45 | 36 |
| 1.001 - 1.500 | 60 | 48 |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring or external interconnection of electronic equipment.
|
|