| Rating | 80 deg C, 150 Vac, Horizontal flame. |
|
| Insulation | Labeled or complying with manufacturer's AWM procedure. |
|
| Assembly | Consists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size. |
|
| Shield | Optional. |
|
| Covering | Optional. A 6 mil or heavier PVC covering may be extruded over the conductor assembly. |
|
| Jacket | PVC |
| major dia in inches |
| 0.350 or less | 15 mils min average | 12 mils minimum at any point |
| 0.351-0.70 dia | 30 avg | 24 min |
| 0.70l-l.000 dia | 45 avg | 36 min |
| 1.001-1.500 dia | 60 avg | 48 min |
|
| Standard | Appliance Wiring Material UL 758. |
|
| Marking | General. |
|
| Use | Internal wiring. Tags may indicate the following: "300 volts Peak for Electronic use only". |
|