APPLIANCE WIRING MATERIAL
Subj.758
Section
2
Page
2951
Issued:
1978-08-10
Revised:
2008-05-27
Style
2951
Flat Cable.
Rating
105 deg C, 300 Vac, Horizontal flame.
Conductor
36 AWG - 20 AWG solid or stranded round, tinned or bare copper.
Insulation
TPE, 9 mils min average, 7 mils min at any point, 17 mils min edge width. Top and/or bottom layers may form ridges. Extruded or heat laminated construction.
Assembly
Two to 150 conductors laid parallel spaced 0.030 in min between conductors.
Standard
Appliance Wiring Material UL 758.
Marking
General.
Use
Internal wiring of electronic computers and electric business machines.