APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2952 Issued:1979-08-25
Revised:2011-09-28
Style 2952 Laminated Flat Ribbon Cable

Rating60 or 80 deg C, 30 Vac, Horizontal flame.
Conductor40 AWG minimum, material not specified. May include mixed AWG sizes.
InsulationPVC, XLPVC, 7 mils minimum average thickness.
AssemblyTwo to fifty uninsulated wires laid parallel in one plane, laminated between 2 sheets of PVC with or without irradiation. Minimum 26 mils between conductors, 15 mils minimum edge width.
CoveringPVC, 7 mils minimum average thickness, 6 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring of Class 2 Circuits in Electronic Equipment.

UL and the UL Logo are trademarks of UL LLC © 2024