APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2953 Issued:1978-07-31
Revised:2012-03-12
Style 2953 Parallel Cable with Extruded Integral Insulation and Jacket

Rating90 deg C, 600 Vac, Horizontal flame.
ConductorResistance Wire. Any suitable resistance element, (size dependent upon wattage demand); the conductor may have fiberglass yarn or other strength members run in parallel with it, or wound around a polyester, rayon or fiberglass core.
InsulationExtruded PVC, 45 mils minimum average thickness, 40 mils minimum thickness at any point. Web width minimum of 60 mils. Web thickness 30 mils minimum thickness at any point.
AssemblyTwo conductors.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UsePipe heating cable where the acceptability of the combination is to be determined by Underwriters Laboratories Inc.

UL and the UL Logo are trademarks of UL LLC © 2024