Rating | 60 deg C, Voltage not specified, Horizontal flame. |
|
Conductor | 24 AWG - 18 AWG solid or stranded round. |
|
Insulation | Labeled or complying with manufacturer's AWM procedure. |
|
Assembly | One or two pairs of Style 1295 in 24-18 AWG conductor size and One Style 1354 or 1598 in 24-18 AWG conductor size. |
|
Shield | Optional. |
|
Jacket | Extruded PVC, 30 mils minimum average thickness, 24 mils minimum thickness at any point. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | TV Camera Cable. |
|