APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2961 Issued:1978-09-27
Revised:2012-04-13
Style 2961 Multiple-conductor cable using non-integral jacket.

Rating80 deg C, 150 Vac, Cable flame.
Insulated ConductorLabeled or complying with Manufacturer's AWM Procedure having a minimum rating of 80 deg C, 150 Vac.
AssemblyConsists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
CoveringOptional. A 6 mils or heavier PVC covering may be extruded over the conductor assembly.
ShieldOptional.
JacketExtruded PVC
Diameter of cable under jacket in inchesMinimum average thicknessMinimum thickness at any point
0.700 or less45 mils36 mils
0.701-1.50060 mils48 mils
1.501-2.50080 mils64 mils
2.501 and larger110 mils88 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring or external interconnection of electronic equipment.

UL and the UL Logo are trademarks of UL LLC © 2024