APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2969 Issued:1978-12-05
Revised:2019-11-07
Style 2969 Multi-conductor cable using non-integral jacket.

Rating80 deg C, 30 Vac, Cable flame.
Conductor40 AWG minimum. solid or stranded round.
InsulationLabeled or complying with manufacturer's AWM procedure, 3 mils min average.
AssemblyTwo or more conductors, twisted pairs or groups of twisted conductors twisted together. the conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
ShieldOptional.
CoveringOptional.
JacketExtruded PVC
major dia in inches
0.425 or less30 mils min average24 mils minimum at any point
0.426-0.700 dia45 avg36 min
0.701-1.000 dia60 avg48 min
1.001-1.500 dia80 avg64 min
1.501-2.500 dia110 avg88 min
2.501 dia and larger 140 avg112 min
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal or external wiring of Class 2 systems of audio and video equipment and electronic equipment.

UL and the UL Logo are trademarks of UL LLC © 2024