APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2971 Issued:1978-12-18
Revised:2012-04-23
Style 2971 Multiple-conductor cable using non-integral jacket.

Rating60 deg C, 30 Vac, Horizontal flame.
Conductor32 AWG - 20 AWG, solid or stranded.
InsulationExtruded PE, extruded FRPE, extruded XLPE, extruded XLFRPE, extruded foamed PE, extruded foamed FRPE, extruded foamed XLPE or extruded foamed XLFRPE, 5 - 100 mils minimum thickness at any point.
AssemblyTwo to four conductors, insulated singles laid parallel to form flat cable.
ShieldIf conductive PVC shield is used, may form a web between conductors under jacket, and will include a drain wire covered by shield and may appear as edge conductor.
JacketExtruded PVC, 3 - 45 mils minimum thickness at any point, with 0.5 inch maximum interconnecting web.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring of Electronic Equipment in Class 2 Circuits only.

UL and the UL Logo are trademarks of UL LLC © 2025