Rating | 60 deg C, 30 Vac, Horizontal flame. |
|
Conductor | 32 AWG - 20 AWG, solid or stranded. |
|
Insulation | Extruded PE, extruded FRPE, extruded XLPE, extruded XLFRPE, extruded foamed PE, extruded foamed FRPE, extruded foamed XLPE or extruded foamed XLFRPE, 5 - 100 mils minimum thickness at any point. |
|
Assembly | Two to four conductors, insulated singles laid parallel to form flat cable. |
|
Shield | If conductive PVC shield is used, may form a web between conductors under jacket, and will include a drain wire covered by shield and may appear as edge conductor. |
|
Jacket | Extruded PVC, 3 - 45 mils minimum thickness at any point, with 0.5 inch maximum interconnecting web. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal Wiring of Electronic Equipment in Class 2 Circuits only. |
|