APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2973 Issued:1979-01-11
Revised:2012-03-20
Style 2973 Parallel Cable with extruded non-integral jacket.

Rating60 deg C, 30 Vac, Horizontal flame.
Conductor40 AWG minimum.
InsulationExtruded or foamed FRPE, PE, PVC, XLPE or XLPVC, 5 mils minimum thickness at any point, 125 mils maximum thickness.
AssemblyTwo to four conductors. The insulation may be applied directly over the conductor or applied with a spiral wrapped Polyethylene thread (5 mils min, 40 mils max and enclosed with "tubed on" Polyethylene insulation.
ShieldOptional.
CoveringOptional. Extruded PVC, Polyamide, Polyester, PVPF, ETFE or lacquered braids, 2 mils minimum at any point.
JacketExtruded PVC, 10 mils minimum average thickness, 8 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of electronic equipment, Class 2 wiring systems.