APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2976 Issued:1979-02-15
Revised:2012-07-23
Style 2976 Multiple-conductor cable using non-intergral jacket

Rating80 deg C, 300 Vac, VW-1 flame.
Conductor30 AWG - 16 AWG solid or stranded round, tinned or bare, copper or copper alloy.
InsulationFRPE or PE, 15 mils min average, 13 mils minimum at any point.
AssemblyTwo to seven conductors. Edge conductor is an uninsulated drain wire covered by conductive PVC shield and jacket.
ShieldOptional. Extruded black conductive PVC, min. 6 mils, max 16 mils thick, 12-30 mils thick over bare drain wire located as edge conductor. Shield forms Webb, min. 6 mils thick, 6-12 mils wide.
JacketPVC, 15 mils min average, 12 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring