APPLIANCE WIRING MATERIAL
Subj.758
Section
2
Page
2981
Issued:
1979-02-28
Revised:
2008-05-27
Style
2981
Flat Cable.
Rating
60 deg C, 30 Vac, Cable flame.
Conductor
Min 40 AWG, material not specified.
Insulation
Solid or cellular FRPE or PE or PVC or XLPE or XLPVC, 5 mils min. at any point, 100 mils max.
Assembly
Two to Ten Insulated singles laid parallel to form flat cable.
Shield
Optional. Conductive thermoplastic (PVC) Shield, if used, may form a web between conductors under jacket and will include a drain wire covered by thermoplastic shield that may appear as edge conductor.
Jacket
PVC, 15 mils min average, 12 mils minimum at any point. Max 0.5 inch web width. May be irradiated.
Standard
Appliance Wiring Material UL 758.
Marking
General.
Use
Internal Wiring of Electronic Equipment in Class 2 circuits only.
UL and the UL Logo are trademarks of UL LLC © 2025