Rating | 75 deg C, 90 Vac, Horizontal flame. |
|
Conductor | 32 AWG - 20 AWG copper. |
|
Insulation | PE, 6 mils min at any point; Insulation width on outside edges, 6 mils. min. Minimum spacing Between conductors, 5 mils or multiconductor flat cable labeled or complying with the manufacturers procedure. |
|
Assembly | Two or more conductors or flat cable complying with Section 2 of the Manufacturer's AWM Procedure . Maximum 0.375 inch thickness over jacket. Maximum 3.5 inch width on outside of jacket. |
|
Shield | Optional. expanded metallic ground planes, one or both sides. The ground plane may be flat copper or aluminum and may be employed as a solid or mesh constructions. |
|
Jacket | PVC, 30 mils min average, 24 mils minimum at any point. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | External interconnection or internal wiring of electronic equipment. |
|