Rating | 60, 80, 90, 105 deg C, 300 Vac, FT2 flame, Moisture Resisant 60 deg C, 720hr Sunlight Resistance. |
|
Conductor | 20 AWG - 10 AWG solid or stranded round, tinned or bare copper. Mixed AWG sizes may be employed. |
|
Insulation | PVC, 30 mils min average, 27 mils minimum at any point. No. 20AWG uses 18AWG thickness. Any Recognized Component (QMTT2) PVC Compound acceptable for use on either wet location Flexible Cord or on an NEC Type with a "W" in its Type letters designation. See Facing Page for Other Designated Compounds. |
|
Assembly | Two to six conductors, same as type SJTW. |
|
Jacket | PVC, 30 mils min average, 24 mils minimum at any point. Same thickness as for Type SJTW. Any Recognized Component (QMTT2) PVC Compound 720 hour Sunlight Resistance Compound and/or Facing Page for Other Designated Compound. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | External interconnection or internal wiring of outdoor appliances, (such as Snow Blowers and Lawn Mowers). |
|