Rating | 80 deg C, 30 Vac, Cable flame. |
|
Insulated Conductor | Labeled or complying with manufacturer's AWM procedure. 40 AWG minimum. |
|
Assembly | Two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers are optional. |
|
Covering | Optional. Extruded PVC, 6 mils minimum thickness at any point, over the conductor assembly. |
|
Shield | Optional. |
|
Jacket | Extruded PVC. |
| Diameter of cable under jacket* | Minimum average thickness | Minimum thickness at any point |
| 0.700 inch or less | 30 mils | 24 mils |
| * - Major diameter if cable is flat or oval. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. "Low voltage computer cable" may be printed on jacket surface. |
|
Use | Internal Wiring or External Interconnection of Electronic Equipment, class 2 circuits only. |
|