APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2995 Issued:1979-06-07
Revised:2012-03-19
Style 2995 Multiple-conductor cable with extruded non-integral jacket.

Rating80 deg C, 300 Vac, Horizontal flame.
Conductor30 AWG - 16 AWG, solid or stranded.
InsulationExtruded PVC, 15 mils minimum average thickness, 13 mils minimum thickness at any point.
AssemblyTwo to Six conductors.
ShieldOptional.
JacketExtruded PVC, 27 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal or Internal wiring of electrical equipment.