APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2998 Issued:1979-06-07
Revised:2012-05-06
Style 2998 Multiple-Conductor Cable using Non-Integral Extruded Jacket

Rating80 deg C, 300 Vac, Horizontal Flame.
Conductor30 AWG - 16 AWG, Solid or Stranded Round.
InsulationExtruded XLPE, 15 mils minimum average, 13 mils minimum at any point.
AssemblyTwo to six conductors. May be either twisted or parallel, fillers and/or barrier layers optional.
ShieldOptional.
JacketExtruded PVC, 30 mils minimum average, 27 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal Interconnection or Internal Wiring.

UL and the UL Logo are trademarks of UL LLC © 2024