APPLIANCE WIRING MATERIAL
Subj.758 Section 3 Page 30017 Issued:2016-05-19
Revised:New
Style 30017 Single conductor with extruded insulation

Rating125 deg C, 1000 Vac ; Moisture Res 75 (required).
Conductor50 AWG - 2000 kcmil, solid or stranded.
InsulationExtruded XLPE, 30 mils minimum average thickness, 27 mils minimum thickness at any point. See facing page for compound identification or any Type XHHW or XHHW-2 compound per the latest bulletin.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseFor Further Processing into Cables.