APPLIANCE WIRING MATERIAL
Subj.758 Section 3 Page 30028 Issued:2016-11-15
Revised:New
Style 30028 Single Conductor with Extruded Insulation

Rating150 deg C, 600 Vac Horizontal Flame; Oil Res 60 Deg C; Gasoline Resistant
Conductor0.000497 sq mm - 107.2 sq mm, Solid or Stranded Round.
InsulationExtruded XLPE
Conductor Size sq mmmm min avg.mm min. at any point
0.000497-5.2610.380.33
6.631-8.3670.760.69
10.55-33.621.020.91
42.41-107.21.271.14
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.