Rating | 105 deg C, 30000 Vdc, Horizontal flame. |
|
Conductor | 24-10 AWG copper or nickel, or 12-10 AWG aluminum, or 27-20 AWG Resistance Wire; solid or stranded. Or 24-10 AWG solid or stranded coated high strength copper - min 90% conductivity. Aluminum conductors shall be permitted for a 90 deg C maximum operating temperature. Copper conductors may be tinned, silver or nickel plated, heat bonded or overcoated. |
|
Insulation | Extruded XLPE, 20 mils minimum average thickness, 18 mils minimum thickness at any point. |
|
Shield | Required. Bare or coated copper wire braid, or serving. |
|
Covering | Optional. |
|
Jacket | Extruded XLPVC, 15 mils minimum average thickness, 12 mils minimum thickness at any point. |
|
Standard | Appliance Wiring Material UL 758. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal Wiring. |
|