APPLIANCE WIRING MATERIAL
Subj.758 Section 3 Page 30052 Issued:2018-10-01
Revised:2020-02-03
Style 30052 Single Insulated with Extruded Insulation

Rating90 deg C, 1000 Vac.
Conductor36 AWG - 2000 kcmil, solid or stranded.
InsulationExtruded XLPE
conductor sizeMin average thisckness (mils)Min thickness at any point (mils)
36 - 20 AWG108
19-16 AWG1210
15-10 AWG1412
9-6 AWG1917
5-2 AWG2422
1-4/0 AWG2825
250-500 kcmil3935
501-1000 kcmil5651
1001-2000 kcmil7063
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseFor Further Processing into Cables.

UL and the UL Logo are trademarks of UL LLC © 2024