Rating | 200 deg C, 5000 Vac, Horizontal Flame. |
|
Conductor | 22 AWG - 350 kcmil, Solid or Stranded Round. |
|
Separator | Optional |
|
Insulation | Extruded SR |
| AWG Size | mils min average | mils min at any point |
| 22-12 | 45 | 40 |
| 11-3/0 | 85 | 78 |
| 4/0-350kcmil | 110 | 100 |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal Wiring for motor lead application where not subjected to movement or mechanical abuse or where totally enclosed. |
|