Rating | 200 deg C,600 Vac Horizontal flame. |
|
Conductor | 35 AWG - 10 AWG, Resistance Wire. Metal Coated, Coiled around a fiberglass core, straight wires may be placed under the turns of the coiled resistance wire, may employ helically wound or braided glass fiber separator over the coiled resistance wire. |
|
Insulation | Extruded SR - Silicone, 30 mils minimum average thickness, 27 mils minimum thickness at any point |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal Wiring for use in Heaters, Crankcase and Defrost Refrigeration where not subjected to repeated flexing,where the acceptability of the combination has been determined by UL LLC. |
|