APPLIANCE WIRING MATERIAL
Subj.758 Section 3 Page 30097 Issued:2021-07-13
Revised:New
Style 30097 Single Conductor with Extruded Insulation

Rating150 deg C, 750 Vac, Horizontal flame.
Conductor30 AWG - 750 kcmil, solid or stranded. Recognized Component - Magnet Wire (OBMW2), rated 200 degrees C (ANSI Type MW35) may be used.
InsulationExtruded XLPE or XLPO.
Conductor sizeMinimum average thicknessMinimum thickness at any point
30-9 AWG30 mils27 mils
8 AWG45 mils41 mils
7-2 AWG60 mils54 mils
1-4/0 AWG80 mils72 mils
250-500 kcmil95 mils86 mils
501-750 kcmil110 mils99 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral. Tags may indicate the following: 2500 V peak - For Electronic Use Only. Wires employing magnet wire shall be plainly marked on the tag: 1) "Magnet Wire Conductors Employed Special Care is required when terminating." 2) "Employs ANSI Type MW35 magnet wire rated 200 deg C."
UseFor use as Motor Leads or Internal Wiring of Appliances.

UL and the UL Logo are trademarks of UL LLC © 2024