APPLIANCE WIRING MATERIAL
Subj.758 Section 3 Page 30110 Issued:2023-01-03
Revised:2023-01-04
Style 30110 Single Conductor with Extruded Insulation and Extruded or Non-Extruded Covering

Rating150 deg C, 1500 Vdc, Horizontal Flame.
Conductor16 AWG - 600 kcmil, Solid or Stranded Round.
SeparatorOptional.
InsulationExtruded SR
Conductor Sizemils minimum averagemils minimum at any point
16-1 AWG5045
1/0-250 kcmil6055
250-600 kcmil8880
CoveringNon-extruded Synthetic Yarn or extruded SR.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.

UL and the UL Logo are trademarks of UL LLC © 2024