APPLIANCE WIRING MATERIAL
Subj.758
Section
3
Page
3012
Issued:
1959-05-01
Revised:
2009-08-03
Style
3012
Insulated Wire.
Rating
75 deg C, 600 Vac, FT2 flame.
Conductor
8 AWG, solid or stranded copper, tinning, separators and splices same as required for Type RH per UL 44.
Insulation
CP, CPE, EP, EPCV, SBR/NR, Silicone or XLPE, 60 mils minimum average, 54 mils minimum at any point.
Covering
Braid. A wrap may be used in lieu of a braid and shall comply with the requirements outlined in the Standard for Rubber-Covered Wires and Cables. Covering may also be saturated.
Standard
Appliance Wiring Material UL 758.
Marking
General.
Use
In appliances in dry locations where exposed to temperatures not exceeding 75 deg C.