APPLIANCE WIRING MATERIAL
Subj.758 Section 3 Page 3012 Issued:1959-05-01
Revised:2009-08-03
Style 3012 Insulated Wire.

Rating75 deg C, 600 Vac, FT2 flame.
Conductor8 AWG, solid or stranded copper, tinning, separators and splices same as required for Type RH per UL 44.
InsulationCP, CPE, EP, EPCV, SBR/NR, Silicone or XLPE, 60 mils minimum average, 54 mils minimum at any point.
CoveringBraid. A wrap may be used in lieu of a braid and shall comply with the requirements outlined in the Standard for Rubber-Covered Wires and Cables. Covering may also be saturated.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseIn appliances in dry locations where exposed to temperatures not exceeding 75 deg C.
 
UL and the UL Logo are trademarks of UL LLC © 2024