APPLIANCE WIRING MATERIAL
Subj.758 Section 3 Page 3025 Issued:1959-05-01
Revised:2012-07-27
Style 3025 Single conductor with extruded insulation.

Rating75 deg C, 300 Vac, Horizontal flame.
Conductor20 AWG - 16 AWG consisting of No. 30 AWG or smaller copper strands; No. 20 AWG may be solid copper.
InsulationExtruded SRB/NR, 30 mils minimum average thickness, 27 mils min at any point.
CoveringNon-extruded Braid, lacquered or saturated. A non-extruded wrap may be used in lieu of a braid and shall comply with the requirements outlined in the Standard for Fixture Wire, UL 66.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseFor use only in Internal Wiring of Lighting Circuits in Refrigerating Equipment where exposed to temperatures not exceeding 75 deg C.

UL and the UL Logo are trademarks of UL LLC © 2024