APPLIANCE WIRING MATERIAL
Subj.758 Section 3 Page 3080 Issued:1959-05-01
Revised:2009-08-14
Style 3080 Insulated Wire.

Rating150 deg C, 300 Vac, Horizontal flame.
Conductor28 AWG or larger, solid or stranded, Resistance Wire Alloy. A glass braid spacer shall be applied over the conductor Assembly.
InsulationSilicone Rubber, nominal 1/32 inch (not a requirement), 30 mils min average, 27 mils minimum at any point.
CoveringSame as for Type SF-2 Fixture Wire.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseFor use only as Refrigerator Defrost Heater Wire where not subjected to flexing or motion.
 
UL and the UL Logo are trademarks of UL LLC © 2024