APPLIANCE WIRING MATERIAL
Subj.758 Section 3 Page 3089 Issued:1959-05-01
Revised:2012-07-16
Style 3089 Insulated Wire.

Rating60 deg C, 600 Vac, Horizontal flame.
Conductor14 AWG solid or stranded round, tinned or bare copper.
InsulationSRB/NR, 45 mils min average, 40 mils minimum at any point.
CoveringUnsaturated braid.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseIn fixtures or appliances in dry locations, where ordinary code rubber is acceptable.