APPLIANCE WIRING MATERIAL
Subj.758 Section 3 Page 3095 Issued:1959-05-01
Revised:2012-04-26
Style 3095 Single conductor with extruded insulation.

Rating60 deg C, 300 Vac, Horizontal flame.
Conductor16 strands of 30 AWG copper manganese or copper nickel resistance wire.
InsulationExtruded SBR/NR, 60 mils minimum average thickness, 54 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring of Electric Refrigerators manufactured by (see facing page) where the acceptability of the combination has been determined by Underwriters Laboratories, Inc.

UL and the UL Logo are trademarks of UL LLC © 2024