Rating | 60 deg C, 300 Vac, Horizontal flame. |
|
Conductor | 16 strands of 30 AWG copper manganese or copper nickel resistance wire. |
|
Insulation | Extruded SBR/NR, 60 mils minimum average thickness, 54 mils minimum thickness at any point. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal Wiring of Electric Refrigerators manufactured by (see facing page) where the acceptability of the combination has been determined by Underwriters Laboratories, Inc. |
|