APPLIANCE WIRING MATERIAL
Subj.758 Section 3 Page 3160 Issued:1969-05-15
Revised:2011-11-21
Style 3160 Single conductor with extruded Insulation

Rating150 deg C, 300 Vac, Horizontal flame.
ConductorMinimum 0.0015 inch diameter Resistance Wire Alloy spirally applied around a glass or "Aramid" fiber core with a minimum of 20 turns per inch.
InsulationSR - SILICONE, 30 mils min average, 27 mils minimum at any point.
CoveringA closely woven aluminum braid shall be provided over the Heater Wire.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseFor use Only as Refrigerator Defrost Heater Wire where not subjected to flexing or motion.

UL and the UL Logo are trademarks of UL LLC © 2024