APPLIANCE WIRING MATERIAL
Subj.758 Section 3 Page 3175 Issued:1962-07-10
Revised:2011-12-29
Style 3175 Single or multiple conductor with extruded insulation.

Rating90 deg C, 600 Vac, Horizontal flame.
ConductorNo. 8 AWG, 7 x 95/0.005 in.; No. 6 AWG, 7 x 150/0.005 in.; No. 4 AWG, 7 x 7 x 37/0.005 in., tineed copper stranding.
InsulationNR - NEOPRENE, 60 mils min average, 54 mils minimum at any point.
SeparatorClose wind or single braid of bleached, purified, soft, white, (except when identifying tracer is used) cotton and shall completely cover the conductor.
CoveringShall consist of a braid of Polyester of a single color and shall be so applied it will cover the insulation completely.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseIn appliances in dry locations where exposed to temperatures not exceeding 90 deg C.

UL and the UL Logo are trademarks of UL LLC © 2024