APPLIANCE WIRING MATERIAL
Subj.758 Section 3 Page 3232 Issued:1968-01-15
Revised:2012-03-12
Style 3232 Single Conductor with Extruded Insulation

Rating105 deg C, 300 Vac, Horizontal flame.
Conductor26 AWG - 16 AWG tinned, consisting of 40 AWG or larger strands.
InsulationExtruded SR - SILICONE, 15 mils minimum average thickness, 13 mils minimum thickness at any point.
CoveringOptional - Extruded Nylon, 2 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of appliances where totally enclosed.