APPLIANCE WIRING MATERIAL
Subj.758 Section 3 Page 3245 Issued:1970-04-28
Revised:2012-07-11
Style 3245 Single Conductor Cable with Extruded Insulation with an Extruded Non-integral Jacket.

Rating125 deg C, 600 Vac, Horizontal flame, Oil Resistant 80 deg C.
Conductor26 AWG - 2 AWG solid or stranded round, silver plated. Minimum 90% conductivity.
InsulationExtruded XLPE, See facing page for compound designation.
26-12 AWG conductor size15 mils min avg13 mils min at any point
10 AWG20 avg18 min
8-6 AWG30 avg27 min
4-2 AWG40 avg36 min
JacketExtruded XLPVDF - see facing page for compound designation
26-12 AWG conductor size4 mils min average
10 AWG4 avg
8-6 AWG5 avg
4-2 AWG6 avg
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseFor use as Motor Leads or Internal Wiring.