| Rating | 125 deg C, 600 Vac, Horizontal flame, Oil Resistant 80 deg C. |
|
| Conductor | 26 AWG - 2 AWG solid or stranded round, silver plated. Minimum 90% conductivity. |
|
| Insulation | Extruded XLPE, See facing page for compound designation. |
| 26-12 AWG conductor size | 15 mils min avg | 13 mils min at any point |
| 10 AWG | 20 avg | 18 min |
| 8-6 AWG | 30 avg | 27 min |
| 4-2 AWG | 40 avg | 36 min |
|
| Jacket | Extruded XLPVDF - see facing page for compound designation |
| 26-12 AWG conductor size | 4 mils min average |
| 10 AWG | 4 avg |
| 8-6 AWG | 5 avg |
| 4-2 AWG | 6 avg |
|
| Standard | Appliance Wiring Material UL 758. |
|
| Marking | General. |
|
| Use | For use as Motor Leads or Internal Wiring. |
|