APPLIANCE WIRING MATERIAL
Subj.758 Section 3 Page 3247 Issued:1970-12-23
Revised:2012-07-24
Style 3247 Multiple conductor cable using non-integral jacket

Rating60 deg C, 300 Vac, Horizontal flame.
Conductor30 AWG - 16 AWG solid or stranded
InsulationXLPE, 15 mils min average, 13 mils minimum at any point.
Shield38-30 AWG tinned or untinned copper strands applied as a wrap or braid.
JacketPVC, 15 mils min average, 12 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring

UL and the UL Logo are trademarks of UL LLC © 2024