APPLIANCE WIRING MATERIAL
Subj.758 Section 3 Page 3269 Issued:1972-05-11
Revised:2011-10-19
Style 3269 Single-conductor using non-integral covering.

Rating150 deg C, 300 Vac, Horizontal flame, 100 deg C wet.
ConductorMinimum 0.0015 inch diameter Resistance wire alloy, spirally applied around a glass or Aramid fiber core with a minimum of 20 turns per inch.
InsulationExtruded SR, 31 mils minimum average thickness, 28 mils minimum thickness at any point.
CoveringOptional, a closely woven aluminum braid or same as for Type SF-2 Fixture Wire.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring where not subjected to flexing or motion.