Rating | 150 deg C, 300 Vac, Horizontal flame, 100 deg C wet. |
|
Conductor | Minimum 0.0015 inch diameter Resistance wire alloy, spirally applied around a glass or Aramid fiber core with a minimum of 20 turns per inch. |
|
Insulation | Extruded SR, 31 mils minimum average thickness, 28 mils minimum thickness at any point. |
|
Covering | Optional, a closely woven aluminum braid or same as for Type SF-2 Fixture Wire. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring where not subjected to flexing or motion. |
|