APPLIANCE WIRING MATERIAL
Subj.758 Section 3 Page 3308 Issued:1976-09-13
Revised:2011-10-28
Style 3308 Single conductor with extruded insulation

Rating125 deg C, 150 dec C no flexing, 600 Vac, Horizontal flame.
Conductor26 AWG - 4/0 AWG solid or stranded round, tinned or bare copper.
InsulationETHYLENE/ACRYLIC ELASTOMER
26-9 AWG conductor size45 mils min average40 mils minimum at any point
8-2 AWG60 avg54 min
1-4/0 AWG80 avg72 min
See facing page for compound designation.
CoveringOptional. Glass Braid.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of appliances where exposed to temperatures not exceeding 125 deg C. Where no flexing occurs, either after installation or during servicing, temperature not to exceed 150 deg C.

UL and the UL Logo are trademarks of UL LLC © 2024