APPLIANCE WIRING MATERIAL
Subj.758 Section 3 Page 3316 Issued:1977-01-28
Revised:2012-04-23
Style 3316 Single conductor with extruded insulation.

Rating200 deg C, 300 Vac, Horizontal flame.
ConductorMinimum 0.0015 inch diameter Resistance Wire Alloy spirally applied around a glass "Aramid" fibre core with a minimum of 20 turns per inch.
InsulationExtruded SILICONE, 30 mils minimum average thickness, 27 mils minimum thickness at any point.
CoveringSame as for Type SF-2 Fixture Wire.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring of Appliances, such as Gas or Electric Ranges.