| Rating | 200 deg C, 300 Vac, Horizontal flame. |
|
| Conductor | 1 to 11 mil diameter single or paired Resistance Wire Alloy spirally applied around a glass aramid fibre core with a minimum of 20 turns per inch. May have helically wound glass fiber separator over conductor, and/or silicone rubber coating over core. |
|
| Insulation | Extruded SR, 22 mils min average, 20 mils minimum at any point. |
|
| Covering | Optional. Non-extruded, Lacquered Glass Braid. |
|
| Standard | Appliance Wiring Material UL 758. |
|
| Marking | General. |
|
| Use | Heating element in appliances where totally enclosed. |
|