APPLIANCE WIRING MATERIAL
Subj.758 Section 3 Page 3323 Issued:1977-06-27
Revised:2012-04-05
Style 3323 Single conductor with extruded insulation.

Rating200 deg C, 300 Vac, Horizontal flame.
Conductor1 to 11 mil diameter single or paired Resistance Wire Alloy spirally applied around a glass aramid fibre core with a minimum of 20 turns per inch. May have helically wound glass fiber separator over conductor, and/or silicone rubber coating over core.
InsulationExtruded SR, 22 mils min average, 20 mils minimum at any point.
CoveringOptional. Non-extruded, Lacquered Glass Braid.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseHeating element in appliances where totally enclosed.

UL and the UL Logo are trademarks of UL LLC © 2024