APPLIANCE WIRING MATERIAL
Subj.758 Section 3 Page 3324 Issued:1977-06-29
Revised:2012-04-26
Style 3324 Single conductor with extruded insulation.

Rating150 deg C, 300 Vac, FT1 flame.
ConductorMinimum 0.0015 inch diameter resistance wire alloy, spirally applied around a glass "Aramid" fibre core.
InsulationExtruded SR, 16 mils minimum average thickness, 14 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseFor use as Heating Element in Appliances where totally enclosed.