Rating | 60 deg C, 30 Vac, Horizontal flame. |
|
Conductor | 40 AWG minimum, material not specified. |
|
Insulation | XLPE or XLFRPE solid or cellular, 5 mils min at any point, 125 mils maximum. The insulation may be applied directly over the conductor or applied as a spiral wrapped XLPE or XLFRPE thread (5 mils min., 40 mils max) and enclosed with "tubed on" insulation. |
|
Assembly | Insulated conductor with optional inner covering, optional shield, and covering. |
|
Shield | Optional. |
|
Covering | Inner covering (Optional) - Extruded PVC, Polyamide, Polyester, PVDF, ETFE or lacquered braids, 2 mils min. at any point. Outer covering - the same as the inner covering, required over any shield except braided metal. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal Wiring. |
|