APPLIANCE WIRING MATERIAL
Subj.758 Section 3 Page 3334 Issued:1978-01-03
Revised:2012-07-16
Style 3334 Single conductor with extruded or other than extruded insulation.

Rating60 deg C, 30 Vac, Horizontal flame.
Conductor40 AWG minimum, material not specified.
InsulationXLPE or XLFRPE solid or cellular, 5 mils min at any point, 125 mils maximum. The insulation may be applied directly over the conductor or applied as a spiral wrapped XLPE or XLFRPE thread (5 mils min., 40 mils max) and enclosed with "tubed on" insulation.
AssemblyInsulated conductor with optional inner covering, optional shield, and covering.
ShieldOptional.
CoveringInner covering (Optional) - Extruded PVC, Polyamide, Polyester, PVDF, ETFE or lacquered braids, 2 mils min. at any point. Outer covering - the same as the inner covering, required over any shield except braided metal.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.