APPLIANCE WIRING MATERIAL
Subj.758 Section 3 Page 3341 Issued:1978-04-05
Revised:2012-07-16
Style 3341 Single Conductor with Extruded Insulation.

Rating125 deg C, 150 deg C no flexing use, 300 Vac, Horizontal flame.
Conductor26 AWG - 14 AWG solid or stranded round, tinned or bare copper, nickel or silver plated.
InsulationExtruded EPDM, 30 mils min average, 27 mils minimum at any point. See facing page for compound designation.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseMotor Leads and Internal Wiring of Appliances, where no flexing occurs either after installation or during servicing.