| Rating | 80 deg C, 300 Vac, Horizontal flame. |
|
| Conductor | 32 AWG - 16 AWG solid or stranded, tinned, bare or silver plated copper, or solid or stranded coated high strength copper - min. 90% conductivity. |
|
| Insulation | Irradiated polyethylene, 15 mils min. average, 13 mils min. at any point. See facing page for compound identification. |
|
| Shield | Optional. |
|
| Jacket | (Optional except when shield is provided) - PVC, 15 mils min. average, 13 mils min. at any point. |
|
| Standard | Appliance Wiring Material UL 758. |
|
| Marking | General. |
|
| Use | Internal Wiring of Appliances, Tags may indicate the following: 600 Volts Peak - For Electronic Use Only. |
|