APPLIANCE WIRING MATERIAL
Subj.758 Section 3 Page 3387 Issued:1980-02-15
Revised:2012-04-23
Style 3387 Coaxial Cable.

Rating80 deg C, 300 Vac, Horizontal flame.
Conductor30 AWG - 16 AWG solid or stranded round.
InsulationExtruded XLPE, 16 mils minimum average thickness, 13 mils minimum thickness at any point.
CoveringOptional - A Fibrous braid, Nylon (2 mils minimum thickness), or 8 mils minimum thickness or Extruded SRPVC or Extruded PVC may be applied between the insulation and shield.
ShieldBraid or spiral wrap construction using steel, nickel - tin - or copper plated steel, or copper - plated iron alloy, or copper - plated nickel wires.
JacketExtruded PVC, 16 mils minimum average thickness, 13 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring of Electronic Equipment where not subjected to repeated flexing in end application.