APPLIANCE WIRING MATERIAL
Subj.758 Section 3 Page 3390 Issued:1980-02-15
Revised:2012-03-31
Style 3390 Multiple-conductor cable using non-integral jacket

Rating105 deg C, 30 Vac, Horizontal flame.
Conductor40 AWG minimum, Material not specified.
InsulationExtruded XLPE, solid or cellular, 4 mils minimum thickness at any point, 100 mils maximum thickness.
ShieldBraid or spiral wrap construction using steel, nickel, tin or copper plated steel, or copper plated iron alloy, or copper plated nickel wires.
JacketExtruded PVC or XLPVC, 5 mils minimum average thickness, 100 mils maximum thickness.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring of Class 2 circuits where not subjected to movement or mechanical damage.

UL and the UL Logo are trademarks of UL LLC © 2024