APPLIANCE WIRING MATERIAL
Subj.758 Section 3 Page 3392 Issued:1980-02-28
Revised:2012-07-16
Style 3392 Single conductor with extruded Insulation using non-integral jacket

Rating80, 90, 105 deg C, 300 Vac, Horizontal flame.
Conductor32 AWG - 16 AWG solid or stranded conductor
InsulationXLPVC, 15 mils min average, 13 mils minimum at any point.
JacketXLPVC, 15 mils min average, 12 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseFor internal Wiring use.