APPLIANCE WIRING MATERIAL
Subj.758 Section 3 Page 3395 Issued:1980-02-28
Revised:2012-07-19
Style 3395 Single Conductor with Extruded Insulation.

Rating60, 80, 90, 105 deg C, 600 Vac, VW-1 flame.
Conductor22 AWG - 14 AWG solid or stranded round.
InsulationInsulation, inner Layer - Extruded XLPVC, 30 mils min average, 27 mils minimum at any point, Insulation, Outer Layer, Extruded irradiated PVC, 28 mils minimum thickness at any point; average thickness not specified.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseDoubly protected internal wiring for use in television receivers and video products.