APPLIANCE WIRING MATERIAL
Subj.758 Section 3 Page 3407 Issued:1980-06-11
Revised:2011-08-11
Style 3407 Single Conductor with Extruded Insulation

Rating200 deg C, 300 Vac, Horizontal flame.
Conductor1 to 11 mil diameter resistance wire alloy conductor spirally applied around a glass yarn or nylon-glass core with a minimum of 10 turns per inch.
InsulationExtruded SR, 30 mils minimum average thickness, 27 mils minimum thickness at any point
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseFor use as a heating element in appliance where totally enclosed.