| Rating | 250 deg C, 600 Vac, Horizontal Flame. |
|
| Conductor | 44 AWG - 26 AWG, solid or stranded. Resistance wire. Conductor may be spirally applied around a core with a min 20 turns per in. |
|
| Insulation | Extruded SR (Silicone Rubber), 30 mils minimum average thickness, 27 mils minimum thickness at any point. |
|
| Covering | Optional, Closely woven fiberglass or aluminum braid. |
|
| Standard | Appliance Wiring Material UL 758. |
|
| Marking | General. |
|
| Use | Internal wiring where not subjected to movement or mechanical damage. |
|