| Rating | 80 deg C, 300 Vac, Horizontal flame. |
|
| Conductor | 30 AWG - 16 AWG solid or stranded, tinned or bare. |
|
| Insulation | Extruded XLPE, 15 mils minimum average thickness, 13 mils minimum thickness at any point. |
|
| Shield | Optional. |
|
| Covering | Optional Covering - A textile braid, nylon jacket with 2 mils minimum thickness or 8 mils of PVC or SRPVC with 8 mils minimum thickness may be applied between the insulation and shield. |
|
| Jacket | Extruded PVC, 15 mils minimum average thickness, 12 mils minimum thickness at any point. |
|
| Standard | Appliance Wiring Material UL 758. |
|
| Marking | General. |
|
| Use | Internal Wiring of Appliances or Electronic Equipment. |
|