APPLIANCE WIRING MATERIAL
Subj.758 Section 3 Page 3438 Issued:1981-11-09
Revised:2012-03-23
Style 3438 Single-Conductor Cable Using Extruded Non-Integral Jacket

Rating80 deg C, 300 Vac, Horizontal flame.
Conductor30 AWG - 16 AWG solid or stranded, tinned or bare.
InsulationExtruded XLPE, 15 mils minimum average thickness, 13 mils minimum thickness at any point.
ShieldOptional.
CoveringOptional Covering - A textile braid, nylon jacket with 2 mils minimum thickness or 8 mils of PVC or SRPVC with 8 mils minimum thickness may be applied between the insulation and shield.
JacketExtruded PVC, 15 mils minimum average thickness, 12 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring of Appliances or Electronic Equipment.